Due to metal enforcement, this densified ply does not bend. It has high load bearing capacity. During the manufacturing of metal enforced ply, sheets of metal wires are assembled in between the layers and it is bonded with PF resin in high pressure hydraulic press.

Application: It can be used in truck, commercial vehicle flooring & other industrial uses. Also in automobile sector deck, ceiling, paneling back rest seat, anti skid flooring etc.

Thickness:12, 16, 19 & 25 mm

Sizes: 2440 to 3350 mm in length 600 to 1820 mm in width

Density: 0.845 to 1.00 gm/cm3

Warranty: 2 years
METAL ENFORCED TRUCK FLOORING

industrial flooring


Pin It


TECHNICAL SPECIFICATIONS
  Dimensions BIS Requirements Observation Values
1 Length
2440 + 6
-6
2442mm
2 Width
1220 + 3
-0
1222mm
3 Thickness 25mm 24.90mm  
4 Squareness 2mm/1000mm 0.95mm
5 Edge Straightness 2mm/1000mm 0.50mm
6 Workmanship & finish Clause Satisfactory  
Physical Properties
7 Density 0.95 gm/cm² 0.96 gm/cm²
8 Moisture Content 5-15% 7.90%
9 Bond Quatlity Test
Boiling - Drying @ 60+_2°c
4 Hrs. - 20 Hrs.
Three Cycles
a) No Visible delamination in glue line and plywood face
b) No forcible separation and fibre should be adhered between plies
Satisfactory

Satisfactory
10 Breaking Strength
250 x 50 x Thickness(mm)
Along - 550kgf
Across - 400kgf
729kgf
493kgf
11 Static Bending Strength
Along the grain M.O.E.
Across the grain M.O.E.
Along the grain M.O.R.
Across the grain M.O.R.
Avg. -7500N/mm²
Ind. - 6700N/mm²
Avg. - 4000N/mm²
Ind. - 3600N/mm²
Avg. - 50
Ind. - 45
Avg. - 30
Ind. - 27
8544.35N/mm²
7353.42N/mm²
5973.94N/mm²
4120.30N/mm²
70.224N/mm²
48.29N/mm²
58.782N/mm²
42.30N/mm²
12 Tensile Strength Along - 55 MPa
Across - 50 MPa
68.32 MPa
57.29 MPa